返回首页

光谱实验室

圆二色光谱仪 Circular dichroism spectrometer(Applied photophysics Chirascan V100)

仪器编号:

联系人:程园/陈中

联系方式:18800270665/18998382617

地址:西湖大学(云谷校区)E10-144

开放范围:自主操作:校内;委托测试:校内、校外 Independent-operation :Internal ; Commissioned Service :Internal/External

  • 仪器编号 LHA19100029 规格
    生产厂家 Applied Photophysics Ltd 型号 Chirascan V100
    制造国家 英国 分类号 010411
    放置地点 云栖校区4#220 出厂日期 2019/09/11
    购置日期 2019/07/15 入网时间 2019/11/01
    主要规格及技术指标 1.光源:150W氙灯 (紫外可见波段), 卤钨灯(近红外波段),汞氙灯(适用于停流动力学),
    2.检测器: 170nm - 1200nm,APD检测器; 850-1700nm ( InGaAs 检测器)。
    3.波长准确度:±0.1nm (160~ 500nm) ±0.5nm (500~1700nm)
    4.光谱带宽可调节范围:0~>25nm。
    5.杂散光:不大于3ppm (200nm)。
    6. CD 噪音水平:
    0.050 mº @ 175 nm
    0.020 mº @ 180 nm
    0.030 mº @ 200 nm
    0.03mdeg @ 750nm
    0.05mdeg @ 1000nm
    (检测条件 :2 second oversampling, 1 nm带宽)
    7. CD测量范围:不小于±9000 m°   
    8.扫描速度:1-10,000 nm/min
    9.电子控温变温系统(含循环浴及磁力搅拌)的温度范围: -40℃-150℃, 准确度:± 0.1℃
    10.在温度连续变化和阶梯式变化的同时进行光谱扫描,研究热力学变化过程( Tm, ΔH )
    11 .荧光偏振/各项异性检测模块: 波长范围不窄于 185-850nm。
    12.快速动力学停流装置
    混合模式:包含两次混合或三路样品混合;
    淬灭停流装置: 样品可以回收用于下一步分析;
    最小死时间:优于1.1毫秒(以20μL样品池,水-水体系为考察标准 );
    13.固体样品透射法检测附件
    14.固体样品反射法检测积分球附件。
    15.阵列式荧光CCD检测模式
    主要功能及特色 1. 用于研究生物大分子的二级结构和三级结构、
    2. 用于生物大分子、有机高分子的热稳定性研究;
    3. 用于各类手性化合物的手性立体结构研究;
    4. 用于分子间相互作用的毫秒级的快速反应动力学机理研究(反应速度、短时间存在过的中间过渡态)等。
    特点:
    有效可检测光谱范围宽: 175-1700nm ;
    样品种类: 液体、固体( 压片式、薄膜类、镀膜类、粉末类)、气态样品, 详情请询。
    工作模式: 静态检测、动力学检测。
    多种光源可选择。
    可提供服务:
    1. 提供各类样品的静态圆二色CD检测;
    2. 提供各类样品的反应动力学分析检测;
    3. 提供仪器的测试使用;


  • 技术资料:https://iscms.westlake.edu.cn/technique/SOP-Chirascan-Plus-V100.pdf


    样品要求:以吸光度在0.2-2.0AU 之间来准备样品。
    1. 蛋白质(多肽)溶液:分子量低于10000时,建议1mg/mL;大于10000时,建议0.5mg/mL。溶液里不能含有DMF或DMSO。如使用除纯水以外的溶剂,需随样品提供少量该溶剂。
    2. 核酸和其它有机小分子以及配位化合物:用1mm或10mm光程的比色皿测量时吸收值低于2.0,并且随样品提供UV-Vis图谱。
    3. 固体:可以制成薄膜,或者溶剂挥发后能够粘附在石英玻璃片上,或者制成KCl或KBr压片,或者有足够的量盖住13mm直径的石英片用于漫反射测试。

  • 圆二色光谱仪(Chirascan-plus V100)

    类型

    项目

    细则

    校内

    校外

    说明

    自主上机

    光谱扫描

    液体样品

    200/

    400/

    需预约并经过培训和考核

    光谱扫描

    固体样品

    变温测试

    -30℃ ~150℃

    停流测试

    反应动力学测试

    委托测试

    光谱扫描

    液体样品

    300/

    500/

    复杂样品等特殊测试,价格需面议

    光谱扫描

    固体样品

    变温测试

    -30℃ ~150℃

    停流测试

    反应动力学测试

    培训

    仪器培训

    一对一/一对二培训;同等内容的第二次培训,收费1.5

    300/

    500/

    /

  • Instrument No.20103104-9004Specification

    ManufactureApplied Photophysics LtdModelChirascan V100

    Made inUnited StatesClassification No010411

    Location4#220Manufacture date11/09/2019

    Purchase Date15/7/2019Internet access time1/11/2019

    Main Technical specifications

    1. Light source: 150W xenon lamp (UV-visible), halogen lamp (NIR), mercury xenon lamp (applicable to stopped-flow unit),

    2. Detector: 170nm-1200nm, APD detector; 850-1700nm, InGaAs detector.

    3. Wavelength accuracy: ±0.1nm (160 ~ 500nm) ±0.5nm (500 ~ 1700nm)

    4. Adjustable range of spectral bandwidth: 0 ~ >25nm.

    5. Stray light: less than 3ppm (200nm).

    6. CD noise level:

    0.050 m @ 175 nm

    0.020 m @ 180 nm

    0.030 m @ 200 nm

    0.03 mdeg @ 750 nm

    0.05 mdeg @ 1000 nm

    (detection conditions: 2 second oversampling, 1 nm bandwidth)

    7. Measurement range of CD: not less than ±9000 m°

    8. Scanning speed: 1-10,000 nm/min

    9. Electronic temperature control system (including cyclic bath and magnetic stirring) : -40℃-150℃, accuracy: ± 0.1℃

    10. Spectral scanning together with temperature continuous and stepped ramping to study thermodynamic process (Tm, Δ H)

    11. Fluorescence polarization/anisotropy detection module: the wavelength range not narrower than 185-850nm.

    12. Fast kinetics stopped flow device

    Mixing mode: contains two or three samples mixing;

    Quench stopped flow device: samples can be recovered for further analysis;

    Minimum dead time: better than 1.1 ms (20-micrometer sample, water-water system as the standard);

    13. Solid sample transmission measurement accessory

    14. Solid sample reflection integrating sphere accessory.

    15. Array fluorescent CCD detection.


    Main functions and features

    Functions:

    1. Study the secondary and tertiary structures of biological macromolecules;

    2. Study the thermal stability of biological macromolecules and organic polymers;

    3. Study on chiral stereoscopic structures of various chiral compounds;

    4. Study the millisecond rapid-reaction kinetics mechanism of intermolecular interaction (reaction speed, intermediate transition state existing for a short time), etc.

    Features:

    Effective detectable spectral range: 175-1700nm;

    Sample types: liquid, solid (tablet, film, coating, powder), gas samples, please inquire for details.

    Working mode: Static, Kinetics.

    A variety of light sources are available.

    Services available:

    1. Provide static circular dichroic CD detection;

    2. Provide reaction kinetics analysis;

    3. Provide the use of the instrument;


  • Informations:

    Sample requirements: prepare samples with an absorbance between 0.2 and 2.0AU.

    1.Protein (polypeptide) solution: 1mg/mL is recommended when the molecular weight is less than 10000; if the molecular weight exceed 10000, 0.5mg/mL is recommended. Sample solution can’t include DMF or DMSO. If use non-water solvent, a small amount of this solvent must be supplied as “Blank”.

    2.Nucleic acids, other small organic molecules and coordination compounds: the absorbance value should be less than 2.0 measured in 1mm or 10mm cuvette, and UV-VIS spectra should be provided with the CD spectra of samples.

    3.Solid: it can be made into a thin film, or it can stick to the quartz glass after solvent evaporation, or it can be pressed into KCl or KBr tablet, or it is enough to covers the 13mm diameter quartz sheet for diffuse reflection test.


  • Operation Types

    Items

    Requirements

    Internal prices

    External prices

    Comments

    Independent operation

    Spectrum scanning

    Liquid sample

    ¥200/hour

    /

    After being well-trained and authorized, Make an appointment online

    Spectrum scanning

    Solid sample

    Temperature-control measurement

    -30℃ ~150℃

    Stopped flow

    Fast reaction kinetic test

    Commissioned test

    Spectrum scanning

    Liquid sample

    ¥300/hour

    ¥400/hour

    For special measurement such as complex samples, the price should be negotiable

    Spectrum scanning

    Solid sample

    Temperature-control measurement

    -30℃ ~150℃

    Stopped flow

    Fast reaction kinetic test

    Training

    Instrument training

    One-on-one or one-on-two training. The first training session is normal charge. Any subsequent training for the same instrument will be charged as a rate of 1.5 times.

    ¥300/hour

    /

    /

Baidu
map